Is Your Community Ready for Winter? A Guide to Irrigation Blowouts

10/13/2026

0 Comments

 
By: ​Alex German - Avalon Landscapes
Idaho’s freezing winter temperatures can damage irrigation piping, valves, pumps, sprinkler heads, filters, and backflow-prevention assemblies when water remains trapped in the system. Communities should winterize irrigation systems before sustained freezing weather arrives, using procedures appropriate for the property’s location, water source, and system design.

Recommended timing:
Winterization should be completed before the first significant freeze, not simply after the irrigation district or municipality ends seasonal water delivery. Timing varies considerably across Idaho:
​
  • Treasure Valley communities commonly winterize during October. The City of Meridian recommends completing sprinkler blowouts before October 31.
  • Associations should schedule contractors early because qualified irrigation companies are often heavily booked once freezing weather enters the forecast. 
Basic winterization procedure:

A qualified irrigation professional should generally:
  1. Inspect and document the system. Review and identify shutoff valves, controllers, pumps, filters, backflow assemblies, drains, and blowout connections.
  2. Shut off the water supply. Close the association’s irrigation isolation valve or coordinate shutdown with the irrigation district, municipality, or other water provider. Shutting off seasonal water alone does not remove water trapped in private association piping.
  3. Protect pumps and related equipment. Disconnect, drain, and protect pumps as required by the manufacturer. Drain filters, pump housings, exposed piping, and other components that may retain water.
  4. Drain the system. Open manual drains and allow gravity-drain systems to empty completely. Confirm that water is not being discharged where it could create erosion, icing, or property damage.
  5. Blow out appropriate piping. Where the system requires compressed-air winterization, connect at the designated blowout point and clear each zone separately. Use equipment that has the proper pressure limits and adequate air volume. Cycle through the system until water is removed, without running a zone longer than necessary.
  6. Protect the backflow assembly. Drain, insulate, remove, or otherwise protect exposed backflow equipment. Compressed air should not be routed through a backflow assembly unless the assembly manufacturer and system design specifically permit it.
  7. Place controllers in winter mode. Turn watering schedules off or select the controller’s standby/winter setting. Power may need to remain on to retain programming or protect certain controller functions.
  8. Complete a final inspection. Confirm that drains are properly positioned, exposed components are protected, valve boxes are secure, pumps are off, and no water remains in vulnerable equipment.

Safety and contractor qualifications
Compressed air can damage irrigation components and cause sprinkler heads or fittings to become dangerous projectiles. Large community systems also require careful control of air pressure and volume. For that reason, associations should use a qualified and insured irrigation contractor familiar with commercial or common-area systems. 
0 Comments



Leave a Reply.

    ​Thank You Sponsors

    Picture
    Picture
    Picture
    Picture
    Picture

    Archives

    October 2026
    September 2026
    August 2026
    July 2026
    June 2026
    April 2026
    March 2026
    February 2026
    December 2025
    October 2025
    September 2025
    August 2025
    July 2025
    June 2025
    May 2025
    April 2025
    March 2025
    February 2025
    January 2025
    December 2024
    October 2024
    September 2024
    August 2024
    July 2024
    April 2024
    March 2024
    February 2024
    January 2024
    December 2023
    October 2023
    September 2023
    August 2023
    July 2023
    June 2023
    May 2023
    April 2023
    March 2023
    February 2023
    January 2023
    December 2022
    November 2022
    October 2022
    September 2022
    August 2022
    July 2022
    June 2022
    May 2022
    April 2022
    March 2022
    January 2022
    November 2021
    October 2021
    August 2021
    July 2021
    June 2021
    May 2021
    April 2021
    March 2021
    February 2021
    January 2021
    December 2020

    Categories

    All
    Community
    COVID
    Cyber
    Meetings
    Mental Health
    Operations & Vendor Management
    Snow

    RSS Feed

Picture
Heather Brownson
Chapter Executive Director

(208) 918-4717
PO BOX 393
Meridian, ID 83680
[email protected]
  • Home
  • Events
  • Sponsor
  • Membership
    • CAI Resources
  • Legislation
  • About
  • Industry Job Opportunities
  • Contact
  • Blog